Home / Rapid Test Reagents / RactopamineRapid Test Strip

RactopamineRapid Test Strip

rapid testReagents · LFG01502 · Yetta Bio

RactopamineRapid Test Strip - rapid testReagents - Yetta Bio

RactopamineRapid Test Strip

Rapid Test Reagents · Food Safety Rapid Testing

LFG01502📦 10T📝 Colloidal Gold Strip · For livestock/poultry tissue, urine · 6 samples≤20 min

Colloidal Gold Strip · For livestock/poultry tissue, urine · 6 samples≤20 min

← Rapid Test Reagents List
📦
Spec
10T
🏷️
SKU
LFG01502
🎯
LOD
Not Detected (ND)
MARA Announcement No.176
🔬
Method
Colloidal Gold
🧪
Sample Type
livestock/poultry tissue, urine
⏱️
Test Time
6 samples≤20 min
Performance
Colloidal Gold · 6 samples≤20 min · For livestock/poultry tissue, urine · Shelf Life: 12 months
🌡️
Storage
Store at 2–30°C away from light
📅
Shelf Life
12 months
📜
Regulatory Basis
Rectification Office Letter [2010] No.50
KJ 201712
🔧Required Equipment & Consumables
🔬Equipment
(1) homogenizer, (2) balance (resolution 0.01 g) , (3) vortex mixer, (4) Centrifuge , (5) water bath, (6) Pipette Set (20-200µL, 100-1000µL) , (7) Colloidal Gold Analyzer (Optional)
📦Consumables
15 mL Centrifuge Tube
📋Test Procedure Guide
1
📝 Sample Preparation
Weigh 4.00±0.05 g homogenized sample into a 15 mL Centrifuge Tube. (Screw-cap 15 mL centrifuge tube recommended., snap-cap tubes may pop open when heated) Add 500 μL Sample Extractant, vortex1min. place in a 80°C water bathwater bath10min后Take Out, 4000rpmroom temperature (20–25°C) Centrifuge5min, 待upper layerClearSolution体cool toroom temperatureAfter That, ImmediatelyassampleSolution.
2
🧪 Test Procedure
Please read the operating instructions carefully before starting the experiment. Allow the test card and test solution to return to room temperature before use. Remove the reagent container and test strip bag from the original packaging. After opening, take out the required number of microwell reagents and test cards, and label them. Use within 60 min. Using a pipette, add 200 μL of test sample solution into the microwell, mix thoroughly by slowly pipetting to ensure full mixing with the microwell reagent. Incubate at room temperature for 5 min, then using a pipette, vertically add approximately 100 μL of the mixed solution into the sample well (S well), or use the disposable dropper provided in the kit to slowly and vertically add 3 drops of the mixed solution into the sample well (S well). Start timing when the liquid begins to flow. Allow to react for 5 min, then immediately interpret the result according to the schematic diagram; results read at other times are invalid.
Purchase Inquiry