Home / Rapid Test Reagents / Potassium Aluminum Sulfate

Potassium Aluminum Sulfate

Rapid Test Reagents · Yetta Bio

Potassium Aluminum Sulfate - rapid testReagents - Yetta Bio

Potassium Aluminum Sulfate

Rapid Test Reagents · Food Safety Rapid Testing

/📦 100 Tests📝 Rapid Test · For livestock/poultry tissue, urine · Project-dependent

Rapid Test · For livestock/poultry tissue, urine · Project-dependent

← Rapid Test Reagents List
📦
Spec
100 Tests
🏷️
SKU
/
🎯
LOD
10.0 μg/kg
GB 2761-2017
🔬
Method
Fluorescence Quantitative
🧪
Sample Type
livestock/poultry tissue, urine
Performance
Fluorescence Quantitative · For livestock/poultry tissue, urine · LOD10.0 μg/kg · Shelf Life: 12 months
🌡️
Storage
Store at 2–8°C
📅
Shelf Life
12 months
🔧Required Equipment & Consumables
🔬Equipment
(1) Pipette Set (20–200 μL, 100–1000 μL) , balance: (0.01 g) , vortex mixer, Sample Grinder, 500 mL Graduated Cylinder , sieve, Centrifuge (Min. Speed >4000r/ min) (Optional) , Constant Temp.Incubator, Fluorescence Reader
📦Consumables
(1) 50 mL Centrifuge Tube , (2) 2 mL Centrifuge Tube
📋Test Procedure Guide
1
Sample Prep
Take 300-500 g representative sample, Grind until ≥90% of particles pass through a 20-mesh sieve; Weigh 5.00±0.05 g sample into a 50 mL Centrifuge Tube, add 25 mL 50%ethanol-water extraction solution, 用vortex mixer 2600-2800 rpmSufficientlyShake3 min, Shake后Immediatelypour into2mL Centrifuge Tube; Handheld/PalmCentrifugeCentrifuge2 min; Collect supernatantSolution待Dilute; SamplediluentSufficientlyMix well; 取500 μLSamplediluent于2 mL Centrifuge Tube, add 100 μL待diluent, Mix well后Centrifuge1 minready for testing. (ObservesupernatantWhetherClear, if impurities are presentthenneedneed toappropriately extendCentrifugeTime) 注 2: Note: Due to highly uneven mycotoxin distribution in samples, proportionally increasing sample and extraction volumes improves repeatability. We offer three sample prep solutions for sample sizes of 5 g, 10 g, and 20 g.
2
Detection
Turn on the Thermostatic Incubator; ready to use once temperature reaches 37°C . Please read this manual and the fluorescence reader operating instructions carefully before the experiment. Allow the test card and the sample to be tested to return to room temperature before use. Remove the test card from its original packaging, mark it, and use it immediately. Use a pipette to draw 100 μL of the sample to be tested and add it vertically into the sample well. Place on an incubator at 37°C and incubate for 8 minutes. Place the test card in a fluorescence reader to read the results.